head_bg

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have quite a few great team customers very good at internet marketing, QC, and dealing with kinds of troublesome trouble while in the output approach for Heparin Sodium Solution, Aspira Pleural Catheter, Soft Hose Oxygen Tubing, If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us.
OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng Detail:

ClinicalApplication Applied Department For Symptom
  Big and small general surgical and abdominal operation Esophagus cancer, rectal cancer, colon cancer, gastric cancer , choleliiiasis. upper gastrointestinal hemorrhage, liver cancer, operation post bile duct and pancreatitis, liver and spleen operation
  Gastrointestinal surgical operation Gastroduodenal perforation, gastroduodenal ulceration hemorrhea. gastrorrhagia. gastroduodenal
Reduce Gastrointestinal pressure Gastroenterology department Gastroduodenal cicatricial pyloric obstruction acute diffuse peritonitis. acute gastric dilatation. Intestinal obstruction, gastric retention
  Neurosurgery department Concomitant gastric stress ulceration caused by craniocerebral mjury
  Thoracic surgery department Big and small surgical chest operation
  Orthopedics department Operational post application of spine and lumbar
  Neurology department Dysphagia caused by brain diseases (encephalorrhagia and cerebral infarction)
  Digestive Department Gastrointestinal dysfunction, malnutrition
  Oncology department Laryngeal cancer, esophagus cancer
Intestinal nutrition Respiratory department Machinery ventilates patient .reflux aspiration
  ICU Stupamus patient aphasia, severe pancreatitis
  Stomatology department Aphthous after
  Bums department Burnt throat. moderate and severe bums

 

  Pediatric department Neonatal stress ulcer, insufficiency of sucking swallowing reflex and gastrointestinal motility
Gastric lavage Emergency department Toxic

Feeding catheter consists of tube, connector, double caps, guidance cap/wire, connecting tube (only for B type). X-ray line is printed on tube. The tube is made of thermoplastic polyurethane elastomer (TPU).

The catheter is disposable and sterile. It is sterilized by oxirane. Residual quantity≤10ug/g. Cytotoxicity≤1. No mucosal stimulus response or delayed hypersensitivity. We suggest that catheter should not indwell in body over 30 days or submit to doctor’s opinion.

1.Before application, operator need to check catheter and prepare other tool.

2.Plugging: After wrapping package, operator help patient rely on bed for confirming length (adult-45~55 cm) then cleaning nostril and narcotizing nasal cavity. Catheter need to be lubricated then being plugged into nasal cavity. Slowly pushing and rotating, until it reached posterior throat, pushing it when patient swallowing, then catheter can be pushed into stomach. Pulling out guidance wire when catheter reaches needed position. At last, catheter need to be fixed on face by bandage.

3.Single and double lumen feeding catheter: Opening double cap will decrease gastrointestinal pressure by discharging or sucking fluids. Then cap need to be closed.

4.Triple lumen feeding catheter (A/B): Opening double cap will decrease gastrointestinal pressure by discharging or sucking fluids. Feeding food and medicine: Firstly, some warm water need to be injected into stomach (30ml once per day). Then fluid food or medicine are injected. After that, operator injects some warm water again for preventing food barrage. Barrage will cause enterogastritis.

5. Pulling: Putting plate under patient’s under jaw. Clipping end of catheter (avoid reflux when pulling). Operator put catheter in plate and slowly remove bandage. Operator pull and clean catheter wrapped by gauze when patient doing expiration.When it reached throat, operator pull it rapidly. Pulled catheter should be pulled in plate. Then operator clean patient’s face, nose and mouth.


Product detail pictures:

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng detail pictures

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng detail pictures

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng detail pictures

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng detail pictures

OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng detail pictures


Related Product Guide:

We believe that long time period partnership is a result of top of the range, value added services, rich expertise and personal contact for OEM Customized Emptying A Urinary Drainage Bag - Feeding Catheter – Zhancheng , The product will supply to all over the world, such as: Jamaica, Amman, Angola, During in 11 years, We've participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
  • Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Ella from Slovenia - 2017.09.09 10:18
    We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Amy from Croatia - 2017.10.25 15:53
    Write your message here and send it to us